Real-time AQtestNET Help
Type Curve Solution Theis Equation
What is it?
Type curves can be used to represents the theoretical response of
an aquifer to a pumping test. By graphically "matching" data to a
type curve, parameters for the data (such as transmissivity) can be
estimated. Type curves are derived from flow equations
with specified initial and boundary conditions and are
typically dimensionless (such as a dimensionless pressure [head]
vs. a dimensionless time). Depending on the complexity of the model,
a single type curve or a family of type curves may be used.
Gringarten (1987)
How to use it:
1) Choose Aquifer Type and Image
Select the aquifer type and image.
Note: if aquifer type is changed, data need to be re-entered.
2) Define Pump Test Parameters
Assign values to the well pumping rate,
and the distance between the pumping well and monitoring well.
3) Add Observation Data
Observation data should be entered in "Time,Value" format with one observation
on each line. "Time" is the elapsed time since the start of the test,
and "Value" is the water level (drawdown/elevation/depth).
Make sure that the time and value units match those in the
observation data. Click "Plot/Update Curves" to display data.
4) Match Data to Type Curve and Calculate Parameters
Drag data over type curve so it falls on the curve.
Then click inside the data range to register the "match".
If using Unconfined Neuman type curve, user can create matches
for both early and late stage data.
If needed enter additional fit parameters observed
on the type curve image.
Click "Calculate Values from Image" to compute parameters.