Controlrule

Controls

Control Rules determine how pumps and regulators in the conveyance system will be adjusted over the course of a simulation. The use of control rules is explained in the following topics:



Rule Format

Each control rule is a series of statements of the form:

RULE ruleID

IF condition_1
AND condition_2
OR condition_3
AND condition_4
 Etc.


THEN action_1
AND action_2
 Etc.


ELSE action_3
AND action_4
 Etc.


PRIORITY value


where keywords are shown in boldface and ruleID is an ID label assigned to the rule, condition_n is a Condition Clause, action_n is an Action Clause, and value is a priority value (e.g., a number from 1 to 5).


Each rule clause must begin with one of the boldface keywords shown above, and only one clause per line is allowed.


Only the RULE, IF and THEN portions of a rule are required; the ELSE and PRIORITY portions are optional.


Blank lines between clauses are permitted and any text to the right of a semicolon is considered a comment.


When mixing AND and OR clauses, the OR operator has higher precedence than AND, i.e.,

"IF A or B and C" is equivalent to "IF (A or B) and C".

If the interpretation was meant to be "IF A or (B and C)" then this can be expressed using two rules as in "IF A THEN..." and "IF B and C THEN..."


The PRIORITY value is used to determine which rule applies when two or more rules require that conflicting actions be taken on a link. A conflicting rule with a higher priority value has precedence over one with a lower value (e.g., PRIORITY 5 outranks PRIORITY 1). A rule without a priority value always has a lower priority than one with a value. For two rules with the same priority value, the rule that appears first is given the higher priority.


back to top
Condition Clauses

A Condition Clause of a Control Rule has the following formats:

 object id attribute relation value

 object id attribute relation object id attribute

where
  • object = a category of object
  • id = the object's ID label
  • attribute = an attribute or property of the object
  • relation = a relational operator (=, <>, <, <=, >, >=)
  • value = an attribute value


  • Some examples of condition clauses are:

     GAGE G1 6-HR_DEPTH > 0.5

     NODE N23 DEPTH > 10

     NODE N23 DEPTH > NODE 25 DEPTH

     PUMP P45 STATUS = OFF

     LINK P45 TIMEOPEN >= 6:30

     SIMULATION CLOCKTIME = 22:45:00

    The objects and attributes that can appear in a condition clause are as follows:
    Object Attribute Value
    GAGE INTENSITY
    n-HR_DEPTH
    numerical value
    numerical value
    NODE DEPTH
    MAXDEPTH
    HEAD
    VOLUME
    INFLOW
    numerical value
    numerical value
    numerical value
    numerical value
    numerical value
    LINK or CONDUIT DEPTH
    FLOW
    FULLFLOW
    DEPTH
    MAXDEPTH
    VELOCITY
    LENGTH
    SLOPE
    STATUS
    TIMEOPEN
    TIMECLOSED
    numerical value
    numerical value
    numerical value
    numerical value
    numerical value
    numerical value
    fractional value
    OPEN or CLOSED
    decimal hours or hr:min
    decimal hours or hr:min
    PUMP STATUS
    SETTING
    FLOW
    ON or OFF
    pump curve multiplier
    numerical value
    ORIFICE SETTING fraction open
    WEIR SETTING fraction open
    OUTLET SETTING rating curve multiplier
    SIMULATION TIME

    DATE
    MONTH
    DAY
    DAYOFYEAR
    CLOCKTIME
    elapsed time in decimal hours or hr:min:sec
    month/day/year
    month of year (1-12)
    day of week (Sunday = 1)
    day of year (month/day)
    time of day in hr:min:sec


    Gage INTENSITY is the rainfall intensity for a specific rain gage in the current simulation time period. Gage n-HR_DEPTH is a gage's total rainfall depth over the past n hours where n is a number between 1 and 48.

    TIMEOPEN is the duration a link has been in an OPEN or ON state or have its SETTING be greater than zero; TIMECLOSED is the duration it has remained in a CLOSED or OFF state or have its SETTING be zero.


    back to top
    Action Clauses

    An Action Clause of a Control Rule can have one of the following formats:

     PUMP id STATUS = ON/OFF

     CONDUIT id STATUS = OPEN/CLOSED

     PUMP/ORIFICE/WEIR/OUTLET id SETTING = value

    The meaning of SETTING depends on the object being controlled:
  • for Pumps it is a multiplier applied to the flow computed from the pump curve (or relative pump speed for a TYPE5 pump).
  • for Orifices it is the fractional amount that the orifice is fully open (orifice control is accomplished by lowering or raising a horizontal gate from the top of the orifice),
  • for Weirs it is the fractional amount of the original freeboard that exists (i.e., weir control is accomplished by moving the crest height up or down),
  • for Outlets it is a multiplier applied to the flow computed from the outlet's rating curve.


  • Some examples of action clauses are:

     PUMP P67 STATUS = OFF

     ORIFICE O212 SETTING = 0.5


    back to top
    Modulated Controls

    Modulated Controls are control rules that provide for a continuous degree of control applied to a pump or flow regulator as determined by the value of some controller variable, such as water depth at a node, or by time. The functional relation between the control setting and the controller variable can be specificed by using a Control Curve, a Time Series, or a PID controller. Some examples of modulated control rules are:

     RULE MC1
     IF NODE N2 DEPTH >= 0
     THEN WEIR W25 SETTING = CURVE C25


     RULE MC2
     IF SIMULATION TIME > 0
     THEN PUMP P12 SETTING = TIMESERIES TS101


     RULE MC3
     IF LINK L33 FLOW <> 1.6
     THEN ORIFICE O12 SETTING = PID 0.1 0.0 0.0


    Note how a modified form of the action clause is used to specify the name of the control curve, time series or PID parameter set that defines the degree of control. A PID parameter set contains three values -- a proportional gain coefficient, an integral time (in minutes), and a derivative time (in minutes). Also, by convention the controller variable used in a Control Curve or PID Controller will always be the object and attribute named in the last condition clause of the rule. As an example, in rule MC1 above Curve C25 would define how the fractional setting at Weir W25 varied with the water depth at Node N2. In rule MC3, the PID controller adjusts the opening height of Orifice O12 to maintain a flow of 1.6 in Link L33.


    back to top
    Named Variables

    Named Variables are aliases used to represent the triplet of <object type | object name | object attribute> (or a doublet for Simulation times) that appear in the condition clauses of control rules. They allow condition clauses to be written as:

     variable relation value

     variable relation variable

    where variable is defined on a separate line before its first use in a rule using the format:

     VARIABLE name = object id attribute

    Here is an example of using this feature:

     VARIABLE Dabc = NODE abc DEPTH

     VARIABLE Defg = NODE efg DEPTH

     VARIABLE P45 = PUMP 45 STATUS

     RULE 1

     IF Dabc > Defg

     AND P45 = OFF

     THEN PUMP 45 STATUS = ON

     RULE 2

     IF Dabc < 1

     THEN PUMP 45 STATUS = OFF

    A variable is not allowed to have the same name as an object attribute.
    Aside from saving some typing, named variables are required when using arithmetic expressions in rule condition clauses.


    back to top
    Arithmetic Expressions

    In addition to a simple condition placed on a single variable, a control condition clause can also contain an arithmetic expression formed from several variables whose value is compared against. Thus the format of a condition clause can be extended as follows:

     expression relation value

     expression relation variable

    where expression is defined on a separate line before its first use in a rule using the format:

     EXPRESSION name = f(variable1, variable2, ...)

    The function f(...) can be any well-formed mathematical expression containing one or more named variables as well as any of the following math functions (which are case insensitive) and operators:
  • abs(x) for absolute value of x
  • sgn(x) which is +1 for x >= 0 or -1 otherwise
  • step(x) which is 0 for x <= 0 and 1 otherwise
  • sqrt(x) for the square root of x
  • log(x) for logarithm base e of x
  • log10(x) for logarithm base 10 of x
  • exp(x) for e raised to the x power
  • the standard trig functions (sin, cos, tan, and cot)
  • the inverse trig functions (asin, acos, atan, and acot)
  • the hyperbolic trig functions (sinh, cosh, tanh, and coth)
  • the standard operators +, -, *, /, ^ (for exponentiation ) and any level of nested parentheses.


  • Here is an example of using this feature:

     VARIABLE P1_flow = LINK 1 FLOW

     VARIABLE P2_flow = LINK 2 FLOW

     VARIABLE O3_flow = Link 3 FLOW

     EXPRESSION Net_Inflow = (P1_flow + P2_flow)/2 - O3_flow

     RULE 1

     IF Net_Inflow > 0.1

     THEN ORIFICE 3 SETTING = 1

     ELSE ORIFICE 3 SETTING = 0.5


    back to top
    Example Rules

    The following are some example control rules:

    ; Simple time-based pump control

     RULE R1

     IF SIMULATION TIME > 8

     THEN PUMP 12 STATUS = ON

     ELSE PUMP 12 STATUS = OFF

    ; Multi-condition orifice gate control

     RULE R2A

     IF NODE 23 DEPTH > 12

     AND LINK 165 FLOW > 100

     THEN ORIFICE R55 SETTING = 0.5


     RULE R2B

     IF NODE 23 DEPTH > 12

     AND LINK 165 FLOW > 200

     THEN ORIFICE R55 SETTING = 1.0


     RULE R2C

     IF NODE 23 DEPTH <= 12

     OR LINK 165 FLOW <= 100

     THEN ORIFICE R55 SETTING = 0

    ; Pump station operation

     RULE R3A

     IF NODE N1 DEPTH > 5

     THEN PUMP N1A STATUS = ON


     RULE R3B

     IF NODE N1 DEPTH > 7

     THEN PUMP N1B STATUS = ON


     RULE R3C

     IF NODE N1 DEPTH <= 3

     THEN PUMP N1A STATUS = OFF

     AND PUMP N1B STATUS = OFF

    ; Modulated weir height control

     RULE R4

     IF NODE N2 DEPTH >= 0

     THEN WEIR W25 SETTING = CURVE C25


    back to top