⛈ StormNET · Real-time Help

Pump

Links & Hydraulic Structures

Pumps are links used to lift water to higher elevations. A pump curve describes the relation between a pump's flow rate and conditions at its inlet and outlet nodes. Five different types of pumps are supported:

Pumpcurvetypes

The input parameters for a Pump are listed in the table below:


Field Description
Name User-assigned pump name.
Start Node Name of node on the inlet side of the pump.
End Node Name of node on the outlet side of the pump.
Pump Curve Name of the Pump Curve which contains the pump's operating data (to make changes to the curve, click 'Edit Curve'). Select 'Ideal pump' (or '*') for a transfer pump whose flow rate equals the inflow rate at its upstream node.
Initial Status Status of the pump (ON or OFF) at the start of the simulation.
Startup Depth Depth at inlet node when pump turns on (ft or m). Enter 0 if not applicable.
Shutoff Depth Depth at inlet node when pump shuts off (ft or m). Enter 0 if not applicable.